Difference between revisions of "BXadmin:Rack usage"

From CCGB
Jump to: navigation, search
(509 Wartik)
(509 Wartik)
 
(7 intermediate revisions by 3 users not shown)
Line 4: Line 4:
 
{{Rack_42U
 
{{Rack_42U
 
|name=RACK-1
 
|name=RACK-1
|44=switch-hp-procurve-9 '''(CCGB)''' ''on UPS-9''
+
|44=switch-hp-procurve-9 '''(CCGB)''' ''on UPS-13''
|43=ift1-jbod1 '''(CCGB)'''|43u=4
+
|42=ift1-jbod1 '''(CCGB)''' ''on UPS-13 and UPS-15''|42u=3
|39=esxi-5 '''(CCGB)''' ''on UPS-8''
+
|39=esxi-5 '''(CCGB)''' ''on UPS-13''
|38=ds4200-1 '''(CCGB)''' ''on UPS-8 and UPS-9''|38u=3
+
|38=ds4200-1 '''(CCGB)''' ''on UPS-13 and UPS-15''|38u=3
|35=esxi-6 '''(Nekrutenko)''' ''moved to MSC''
+
|34=river '''(CCGB)''' ''on UPS-13''
|34=river '''(CCGB)''' ''on UPS-8''
+
|33=jayne '''(CCGB)''' ''on UPS-15''
|33=jayne '''(CCGB)''' ''on UPS-8''
+
|20=ella-md1200 '''(Miller)''' ''on UPS-13''|20u=2
|32=baker '''(Miller)''' ''moved to CB''|32u=2
+
|18=ella '''(Miller)''' ''on UPS-13 and UPS-15''|18u=2
|30=mal '''(Hardison)''' ''moved to CB''|30u=2
+
|16=[[bxa:osiris|osiris]] '''(CCGB)''' ''on UPS-13''|16u=2
|26=mulligan '''(Miller)''' ''moved to CB''
 
|25=badger '''(Hardison)''' ''moved to CB''|25u=2
 
|23=MD-1000 (badger) '''(Hardison)''' ''moved to CB''|23u=3
 
|20=new MD1200 '''(???)''' |20u=2
 
|18=new Dell '''(???)''' |18u=2
 
|16=[[bxa:osiris|osiris]] '''(CCGB)''' ''on UPS-8''|16u=2
 
 
|14=J4200 (osiris) '''(?)''' ''powered off''|14u=2
 
|14=J4200 (osiris) '''(?)''' ''powered off''|14u=2
|6=PDU-14 ''on wall''
+
|3=UPS-13 - APC Smart-UPS RT 6000 '''(CCGB)''' ''powered on''|3u=3
|5=UPS-13 - APC Smart-UPS XL 6000 '''(CCGB)''' ''dead''|5u=3
 
|2=UPS-12 - APC Smart-UPS 2200 '''(CCGB)''' ''dead''|2u=2
 
 
}}
 
}}
 
</div>
 
</div>
Line 28: Line 20:
 
<div style="float: left">
 
<div style="float: left">
 
{{Rack_42U|name=RACK-2
 
{{Rack_42U|name=RACK-2
|44=switch-hp-procurve-4 '''(CCGB)''' ''on UPS-10''
+
|44=switch-hp-procurve-4 '''(CCGB)''' ''on UPS-15''
|43=sanbox-1 '''(CCGB)''' ''on UPS-7''
+
|43=sanbox-1 '''(CCGB)''' ''on UPS-13''
 
|42=sanbox-2 '''(CCGB)''' ''on UPS-8''
 
|42=sanbox-2 '''(CCGB)''' ''on UPS-8''
|41=ift-1 '''(CCGB)''' ''on UPS-8''|41u=4
+
|41=ift-1 '''(CCGB)''' ''on UPS-15''|41u=4
|35=MD1200 (comandra) '''(dePamphilis)''' ''on UPS-9/10''|35u=2
+
|27=tortuga '''(Miller)''' ''on UPS-9''
|33=comandra '''(dePamphilis)''' ''on UPS-9/10''|33u=2
+
|25=herbie '''(Miller)''' ''on UPS-9''|25u=3
|31=brubeck '''(Makova)''' ''moved to MSC''|31u=2
 
|29=MD1200 (brubeck) '''(Makova)''' ''moved to MSC''|29u=2
 
|27=tortuga '''(Miller)''' ''on UPS-10''
 
|25=herbie '''(Miller)''' ''powered off''|25u=3
 
|22=MD1200 (brubeck) '''(Makova)''' ''moved to MSC''|22u=2
 
 
|20=xraid-1 (not aligned) '''(Nekrutenko)''' ''on UPS-9''|20u=3
 
|20=xraid-1 (not aligned) '''(Nekrutenko)''' ''on UPS-9''|20u=3
 
|16=lonnie (not aligned) '''(Nekrutenko)''' ''powered off''
 
|16=lonnie (not aligned) '''(Nekrutenko)''' ''powered off''
 
|15=SHELF
 
|15=SHELF
|8=Dell UPS 3750W '''(?)''' ''dead''|8u=4
+
|7=UPS-15 - APC Smart-UPS RT 6000 '''(CCGB)''' ''powered on''|7u=3
 
|4=UPS-9 - APC Smart-UPS 2200 '''(CCGB)''' ''powered on''|4u=2
 
|4=UPS-9 - APC Smart-UPS 2200 '''(CCGB)''' ''powered on''|4u=2
 
|2=UPS-10 - APC Smart-UPS 2200 '''(CCGB)''' ''powered on''|2u=2
 
|2=UPS-10 - APC Smart-UPS 2200 '''(CCGB)''' ''powered on''|2u=2
Line 50: Line 37:
 
<div style="float: left">
 
<div style="float: left">
 
{{Rack_42U|name=RACK-3
 
{{Rack_42U|name=RACK-3
|44=switch-hp-procurve-8 '''(Nekrutenko)'''
+
|13=PDU-3
|42=PDU-18 '''(Nekrutenko)'''
+
|8=SHELF
|3=BATT-1 '''(Nekrutenko)''' ''on UPS-8''|3u=3
+
|6=UPS-8 - APC Smart-UPS RT 6000 '''(CCGB)''' ''on UPS-8''|6u=3
 +
|3=BATT-1 '''(CCGB)''' ''on UPS-8''|3u=3
 
|
 
|
 
}}
 
}}
Line 59: Line 47:
 
<div style="float: left">
 
<div style="float: left">
 
{{Rack_42U|name=RACK-4
 
{{Rack_42U|name=RACK-4
|44=switch-hp-procurve-6 '''(CCGB)''' ''on UPS-7?''
+
|44=switch-hp-procurve-6 '''(CCGB)''' ''on UPS-?''
|43=saturn '''(Makova)''' ''on UPS-7?''
+
|43=saturn '''(Makova)''' ''on UPS-8''
|42=zoe '''(CCGB)''' ''on UPS-7?''
+
|42=zoe '''(CCGB)''' ''on UPS-8''
|41=inara '''(CCGB)''' ''on UPS-7?''
+
|41=inara '''(CCGB)''' ''on UPS-8''
|40=early '''(CCGB)''' ''on UPS-7?''|40u=5
+
|40=early '''(CCGB)''' ''on UPS-8''|40u=5
|35=storedge-3300-1 (early) '''(CCGB)''' ''on UPS-7?''|35u=2
+
|35=storedge-3300-1 (early) '''(CCGB)''' ''on UPS-8''|35u=2
|33=simon '''(CCGB)''' ''on UPS-7?''
+
|33=simon '''(CCGB)''' ''on UPS-8''
|29=c14 '''(Schuster)''' ''powered off''|29u=2
+
|29=c14 '''(Schuster)''' ''on UPS-?''|29u=2
|27=scofield '''(Nekrutenko)''' ''on UPS-7?''|27u=2
+
|24=esxi-7 '''(Nekrutenko)''' ''on UPS-8''
|24=esxi-7 '''(Nekrutenko)''' ''on UPS-7''
+
|23=1/3 md1k-big (s3) '''(Schuster)''' ''on UPS-?''|23u=3
|23=md1k-7 '''(Schuster)''' ''on UPS-2/3/4''|23u=3
+
|20=2/3 md1k-big (s3) '''(Schuster)''' ''on UPS-?'|20u=3
|20=1/2 md1k-big (s3) '''(Schuster)''' ''on UPS-2/3/4''|20u=3
+
|17=3/3 md1k-big (s3) '''(Schuster)''' ''on UPS-?''|17u=3
|17=2/2 md1k-big (s3) '''(Schuster)''' ''on UPS-2/3/4''|17u=3
+
|12=UPS-7 '''(CCGB)''' ''powered off''|12u=6
|12=UPS-7 '''(CCGB)''' ''powered on''|12u=6
 
 
|6=BATT-2 '''(CCGB)''' ''on UPS-7''|6u=3
 
|6=BATT-2 '''(CCGB)''' ''on UPS-7''|6u=3
 
}}
 
}}
Line 122: Line 109:
 
|36=node008 '''(Schuster)''' ''powered off''
 
|36=node008 '''(Schuster)''' ''powered off''
 
|35=node009 '''(Schuster)''' ''powered off''
 
|35=node009 '''(Schuster)''' ''powered off''
|34=node010 '''(Schuster)''' ''powered off''
+
|33=c15 '''(Schuster)''' ''powered on''|33u=2
|33=node011 '''(Schuster)''' ''powered off''
+
|31=c16 '''(Schuster)''' ''powered on''|31u=2
|32=node012 '''(Schuster)''' ''powered off''
 
|31=node013 '''(Schuster)''' ''powered off''
 
|30=node014 '''(Schuster)''' ''powered off''
 
 
|29=linne '''(Schuster)''' ''powered off''
 
|29=linne '''(Schuster)''' ''powered off''
 
|28=linne-xraid (not aligned, takes up 4u) '''(Schuster)'''|28u=3 ''powered off''
 
|28=linne-xraid (not aligned, takes up 4u) '''(Schuster)'''|28u=3 ''powered off''
|24=node015 '''(Schuster)''' ''powered off''
+
|24=1/2 md1k-7 (s2) '''(Schuster)''' ''powered on''|24u=3
|23=node016 '''(Schuster)''' ''powered off''
+
|21=2/2 md1k-7 (s2) '''(Schuster)''' ''powered on''|21u=3
|22=node017 '''(Schuster)''' ''powered off''
 
|21=node018 '''(Schuster)''' ''powered off''
 
|20=node019 '''(Schuster)''' ''powered off''
 
|19=node020 '''(Schuster)''' ''powered off''
 
 
|18=node021 '''(Schuster)''' ''powered off''
 
|18=node021 '''(Schuster)''' ''powered off''
 
|17=node022 '''(Schuster)''' ''powered off''
 
|17=node022 '''(Schuster)''' ''powered off''
|16=node023 '''(Schuster)''' ''powered off''
+
|11=Backblaze storage pod '''(Schuster)''' ''powered on''|11u=4
|15=node024 '''(Schuster)''' ''powered off''
 
|14=node025 '''(Schuster)''' ''powered off''
 
|13=node026 '''(Schuster)''' ''powered off''
 
|12=node027 '''(Schuster)''' ''powered off''
 
|11=node028 '''(Schuster)''' ''powered off''
 
|10=node029 '''(Schuster)''' ''powered off''
 
|9=node030 '''(Schuster)''' ''powered off''
 
|8=node031 '''(Schuster)''' ''powered off''
 
 
|7=UPS-2 (not aligned) - APC Smart-UPS 2200 '''(Schuster)''' ''powered on''|7u=2
 
|7=UPS-2 (not aligned) - APC Smart-UPS 2200 '''(Schuster)''' ''powered on''|7u=2
 
|5=UPS-4 (not aligned) - APC Smart-UPS 2200 '''(Schuster)''' ''powered on''|5u=2
 
|5=UPS-4 (not aligned) - APC Smart-UPS 2200 '''(Schuster)''' ''powered on''|5u=2
Line 154: Line 126:
 
<div style="float: left">
 
<div style="float: left">
 
{{Rack_42U|name=RACK-7
 
{{Rack_42U|name=RACK-7
|36=node016 '''(Holmes)''' ''moved to CB''
 
|35=node015 '''(Holmes)''' ''moved to CB''
 
|34=node014 '''(Holmes)''' ''moved to CB''
 
|33=Foundry EdgeIron 48G '''(Holmes)''' ''moved to CB''
 
|32=okinawa '''(Holmes)''' ''moved to CB''
 
 
|31=node001 '''(Holmes)''' ''powered off''
 
|31=node001 '''(Holmes)''' ''powered off''
 
|30=node002 '''(Holmes)''' ''powered off''
 
|30=node002 '''(Holmes)''' ''powered off''
Line 170: Line 137:
 
|22=node010 '''(Holmes)''' ''powered off''
 
|22=node010 '''(Holmes)''' ''powered off''
 
|21=node013 '''(Holmes)''' ''powered off''
 
|21=node013 '''(Holmes)''' ''powered off''
|20=Dell MD1000 '''(Huck)''' ''Gone''|20u=3 ''powered off''
 
 
|17=node011 '''(Holmes)''' ''powered off''
 
|17=node011 '''(Holmes)''' ''powered off''
 
|16=node012 '''(Holmes)''' ''powered off''
 
|16=node012 '''(Holmes)''' ''powered off''
|14=Dell PE2850 '''(Huck)''' ''Gone''|14u=2 ''powered off''
 
|12=SHELF
 
 
|10=UPS-1 - APC Smart-UPS 2200 XL '''(Holmes)''' ''powered on''|10u=5u
 
|10=UPS-1 - APC Smart-UPS 2200 XL '''(Holmes)''' ''powered on''|10u=5u
|3=Smart-UPS 2200XL '''(Holmes)''' ''powered off''|3u=3
 
 
}}
 
}}
 
</div>
 
</div>
Line 183: Line 146:
 
{{Rack_42U|name=RACK-8
 
{{Rack_42U|name=RACK-8
 
|42=kaylee '''(Nekrutenko/CCGB)''' ''on UPS-14''
 
|42=kaylee '''(Nekrutenko/CCGB)''' ''on UPS-14''
|41=rochefort '''(Nekrutenko)''' ''moved to MSC''
+
|12=e2-md1000 '''(Miller)'''|12u=3
|40=rochefort-ift-1 '''(Nekrutenko)''' ''moved to MSC''|40u=4
+
|9=e2 '''(Miller)'''|9u=2
|36=rochefort-ift-2 '''(Nekrutenko)''' ''moved to MSC''|36u=4
 
|32=westmalle '''(Nekrutenko)''' ''moved to MSC''
 
|31=westmalle-ift-1 '''(Nekrutenko)''' ''moved to MSC''|31u=4
 
|27=westmalle-ift-2 '''(Nekrutenko)''' ''moved to MSC''|27u=4
 
|23=orval '''(Nekrutenko)''' ''moved to MSC''
 
|22=orval-ift-1 '''(Nekrutenko)''' ''moved to MSC''|22u=4
 
|12=new storage? '''(ella)'''|12u=3
 
|9=ella '''(Miller)'''|9u=2
 
 
|6=UPS-14 - APC Smart-UPS RT 6000 '''(Nekrutenko)''' ''powered on''|6u=3
 
|6=UPS-14 - APC Smart-UPS RT 6000 '''(Nekrutenko)''' ''powered on''|6u=3
 
|3=Battery Pack '''(Nekrutenko)''' ''on UPS-14''|3u=3
 
|3=Battery Pack '''(Nekrutenko)''' ''on UPS-14''|3u=3
Line 202: Line 157:
 
= Computer Building =
 
= Computer Building =
  
{{Rack_42U|name=RCC-C11?
+
{{Rack_42U|name=RCC-C11
 
|21=Foundry EdgeIron 24G-A (okinawa)
 
|21=Foundry EdgeIron 24G-A (okinawa)
 
|20=zeus|20u=4
 
|20=zeus|20u=4
Line 222: Line 177:
 
<div style="float: left">
 
<div style="float: left">
 
{{Rack_42U|name=Rack 1
 
{{Rack_42U|name=Rack 1
|38=bigsky
+
|38=bigsky '''(Nekrutenko)'''
|37=thumper|37u=4
+
|37=thumper '''(Nekrutenko)'''|37u=4
|33=J4400 (thumper)|33u=4
+
|33=J4400 (thumper) '''(Nekrutenko)'''|33u=4
 
|29=??? (Sunfire X4500)|29u=4
 
|29=??? (Sunfire X4500)|29u=4
 
|25=???
 
|25=???
Line 230: Line 185:
 
|23=???
 
|23=???
 
|22=esxi-6 '''(Nekrutenko)'''
 
|22=esxi-6 '''(Nekrutenko)'''
|21=scofield
+
|21=scofield '''(Nekrutenko)'''
|19=supermicro|19u=4
+
|19=??? (supermicro)|19u=4
 
}}
 
}}
 
</div>
 
</div>
Line 237: Line 192:
 
<div style="float: left">
 
<div style="float: left">
 
{{Rack_42U|name=Rack 2
 
{{Rack_42U|name=Rack 2
|40=n0
+
|40=n0 '''(Nekrutenko)'''
|39=n1
+
|39=n1 '''(Nekrutenko)'''
|38=n2
+
|38=n2 '''(Nekrutenko)'''
|37=n3
+
|37=n3 '''(Nekrutenko)'''
|36=n4
+
|36=n4 '''(Nekrutenko)'''
|35=n5
+
|35=n5 '''(Nekrutenko)'''
|34=n6
+
|34=n6 '''(Nekrutenko)'''
|33=n7
+
|33=n7 '''(Nekrutenko)'''
|32=n8
+
|32=n8 '''(Nekrutenko)'''
|31=n9
+
|31=n9 '''(Nekrutenko)'''
|30=n10
+
|30=n10 '''(Nekrutenko)'''
|29=n11
+
|29=n11 '''(Nekrutenko)'''
|28=n12
+
|28=n12 '''(Nekrutenko)'''
|27=n13
+
|27=n13 '''(Nekrutenko)'''
|26=n14
+
|26=n14 '''(Nekrutenko)'''
|25=n15
+
|25=n15 '''(Nekrutenko)'''
|24=n16
+
|24=n16 '''(Nekrutenko)'''
|23=n17
+
|23=n17 '''(Nekrutenko)'''
|22=n18
+
|22=n18 '''(Nekrutenko)'''
|21=n19
+
|21=n19 '''(Nekrutenko)'''
 
|16=brubeck '''(Makova)'''|16u=2
 
|16=brubeck '''(Makova)'''|16u=2
 
|14=md1k (brubeck) '''(Makova)'''|14u=2
 
|14=md1k (brubeck) '''(Makova)'''|14u=2

Latest revision as of 12:17, 7 August 2014

509 Wartik

RACK-1
RU item
44 switch-hp-procurve-9 (CCGB) on UPS-13
43
42 ift1-jbod1 (CCGB) on UPS-13 and UPS-15
41
40
39 esxi-5 (CCGB) on UPS-13
38 ds4200-1 (CCGB) on UPS-13 and UPS-15
37
36
35
34 river (CCGB) on UPS-13
33 jayne (CCGB) on UPS-15
32
31
30
29
28
27
26
25
24
23
22
21
20 ella-md1200 (Miller) on UPS-13
19
18 ella (Miller) on UPS-13 and UPS-15
17
16 osiris (CCGB) on UPS-13
15
14 J4200 (osiris) (?) powered off
13
12
11
10
9
8
7
6
5
4
3 UPS-13 - APC Smart-UPS RT 6000 (CCGB) powered on
2
1
RACK-2
RU item
44 switch-hp-procurve-4 (CCGB) on UPS-15
43 sanbox-1 (CCGB) on UPS-13
42 sanbox-2 (CCGB) on UPS-8
41 ift-1 (CCGB) on UPS-15
40
39
38
37
36
35
34
33
32
31
30
29
28
27 tortuga (Miller) on UPS-9
26
25 herbie (Miller) on UPS-9
24
23
22
21
20 xraid-1 (not aligned) (Nekrutenko) on UPS-9
19
18
17
16 lonnie (not aligned) (Nekrutenko) powered off
15 SHELF
14
13
12
11
10
9
8
7 UPS-15 - APC Smart-UPS RT 6000 (CCGB) powered on
6
5
4 UPS-9 - APC Smart-UPS 2200 (CCGB) powered on
3
2 UPS-10 - APC Smart-UPS 2200 (CCGB) powered on
1
RACK-3
RU item
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13 PDU-3
12
11
10
9
8 SHELF
7
6 UPS-8 - APC Smart-UPS RT 6000 (CCGB) on UPS-8
5
4
3 BATT-1 (CCGB) on UPS-8
2
1
RACK-4
RU item
44 switch-hp-procurve-6 (CCGB) on UPS-?
43 saturn (Makova) on UPS-8
42 zoe (CCGB) on UPS-8
41 inara (CCGB) on UPS-8
40 early (CCGB) on UPS-8
39
38
37
36
35 storedge-3300-1 (early) (CCGB) on UPS-8
34
33 simon (CCGB) on UPS-8
32
31
30
29 c14 (Schuster) on UPS-?
28
27
26
25
24 esxi-7 (Nekrutenko) on UPS-8
23 1/3 md1k-big (s3) (Schuster) on UPS-?
22
21
20 2/3 md1k-big (s3) (Schuster) on UPS-?'
19
18
17 3/3 md1k-big (s3) (Schuster) on UPS-?
16
15
14
13
12 UPS-7 (CCGB) powered off
11
10
9
8
7
6 BATT-2 (CCGB) on UPS-7
5
4
3
2
1
RACK-5
RU item
44 c1 (Schuster) on PDU-17
43 c2 (Schuster) on PDU-17
42 c3 (Schuster) on PDU-17
41 c4 (Schuster) on PDU-17
40 c9 (Schuster) powered off
39 c10 (Schuster) powered off
38 c11 (Schuster) powered off
37 c12 (Schuster) powered off
36 c13 (Schuster) powered off
35 c8 (Schuster) powered off
34 c5 (Schuster) powered off
33 c6 (Schuster) powered off
32 c7 (Schuster) powered off
31 PDU-17 plugged in somewhere...
30 switch-hp-procurve-7 (Schuster) on UPS-6
29 lux (Schuster) on UPS-2 and UPS-3
28
27 HP MSA70 (lux) (Schuster) on UPS-5 and UPS-6
26
25 shelf
24 md1k-6 (s2) (Schuster) on UPS-4 and UPS-6
23
22
21 md1k-5 (s2) (Schuster) on UPS-4 and UPS-5
20
19
18 md1k-4 (s2) (Schuster) on UPS-5 and UPS-6
17
16
15 s2 (Schuster) on UPS-2 and UPS-3
14 s3 (Schuster) on UPS-2 and UPS-3
13 md1k-3 (s3) (Schuster) on UPS-2 and UPS-3
12
11
10 md1k-2 (s3) (Schuster) on UPS-3 and UPS-4
9
8
7 md1k-1 (s3) (Schuster) on UPS-4 and UPS-5
6
5
4 UPS-5 - APC Smart-UPS 2200 (Schuster) powered on
3
2 UPS-6 - APC Smart-UPS 2200 (Schuster) powered on
1
RACK-6
RU item
44 Foundry EdgeIron 48G (Schuster) powered off
43 node001 (Schuster) powered off
42 node002 (Schuster) powered off
41 node003 (Schuster) powered off
40 node004 (Schuster) powered off
39 node005 (Schuster) powered off
38 node006 (Schuster) powered off
37 node007 (Schuster) powered off
36 node008 (Schuster) powered off
35 node009 (Schuster) powered off
34
33 c15 (Schuster) powered on
32
31 c16 (Schuster) powered on
30
29 linne (Schuster) powered off
28 linne-xraid (not aligned, takes up 4u) (Schuster)
27
26
25
24 1/2 md1k-7 (s2) (Schuster) powered on
23
22
21 2/2 md1k-7 (s2) (Schuster) powered on
20
19
18 node021 (Schuster) powered off
17 node022 (Schuster) powered off
16
15
14
13
12
11 Backblaze storage pod (Schuster) powered on
10
9
8
7 UPS-2 (not aligned) - APC Smart-UPS 2200 (Schuster) powered on
6
5 UPS-4 (not aligned) - APC Smart-UPS 2200 (Schuster) powered on
4
3 UPS-3 (not aligned) - APC Smart-UPS 2200 (Schuster) powered on
2
1
RACK-7
RU item
44
43
42
41
40
39
38
37
36
35
34
33
32
31 node001 (Holmes) powered off
30 node002 (Holmes) powered off
29 node003 (Holmes) powered off
28 node004 (Holmes) powered off
27 node005 (Holmes) powered off
26 node006 (Holmes) powered off
25 node007 (Holmes) powered off
24 node008 (Holmes) powered off
23 node009 (Holmes) powered off
22 node010 (Holmes) powered off
21 node013 (Holmes) powered off
20
19
18
17 node011 (Holmes) powered off
16 node012 (Holmes) powered off
15
14
13
12
11
10 UPS-1 - APC Smart-UPS 2200 XL (Holmes) powered on
9
8
7
6
5
4
3
2
1
RACK-8
RU item
44
43
42 kaylee (Nekrutenko/CCGB) on UPS-14
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12 e2-md1000 (Miller)
11
10
9 e2 (Miller)
8
7
6 UPS-14 - APC Smart-UPS RT 6000 (Nekrutenko) powered on
5
4
3 Battery Pack (Nekrutenko) on UPS-14
2
1

Computer Building

RCC-C11
RU item
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21 Foundry EdgeIron 24G-A (okinawa)
20 zeus
19
18
17
16 mulligan
15 baker
14
13 apollo
12
11 mal
10
9 badger
8
7 md1k (badger)
6
5
4 okinawa
3 node016
2 node015
1 node014


MSC

Rack 1
RU item
44
43
42
41
40
39
38 bigsky (Nekrutenko)
37 thumper (Nekrutenko)
36
35
34
33 J4400 (thumper) (Nekrutenko)
32
31
30
29 ??? (Sunfire X4500)
28
27
26
25 ???
24 ???
23 ???
22 esxi-6 (Nekrutenko)
21 scofield (Nekrutenko)
20
19 ??? (supermicro)
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Rack 2
RU item
44
43
42
41
40 n0 (Nekrutenko)
39 n1 (Nekrutenko)
38 n2 (Nekrutenko)
37 n3 (Nekrutenko)
36 n4 (Nekrutenko)
35 n5 (Nekrutenko)
34 n6 (Nekrutenko)
33 n7 (Nekrutenko)
32 n8 (Nekrutenko)
31 n9 (Nekrutenko)
30 n10 (Nekrutenko)
29 n11 (Nekrutenko)
28 n12 (Nekrutenko)
27 n13 (Nekrutenko)
26 n14 (Nekrutenko)
25 n15 (Nekrutenko)
24 n16 (Nekrutenko)
23 n17 (Nekrutenko)
22 n18 (Nekrutenko)
21 n19 (Nekrutenko)
20
19
18
17
16 brubeck (Makova)
15
14 md1k (brubeck) (Makova)
13
12 md1k (brubeck) (Makova)
11
10
9
8
7
6
5
4
3
2
1
Rack 4
RU item
44
43
42
41
40 rochefort (Nekrutenko)
39 rochefort-ift1 (Nekrutenko)
38
37
36
35 rochefort-ift2 (Nekrutenko)
34
33
32
31 westmalle (Nekrutenko)
30 westmalle-ift1 (Nekrutenko)
29
28
27
26 westmalle-ift2 (Nekrutenko)
25
24
23
22 orval (Nekrutenko)
21 orval-ift1 (Nekrutenko)
20
19
18
17 promise
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1