Difference between revisions of "SLab:Todo"
(→Problem Description) |
(→Next Section) |
||
Line 119: | Line 119: | ||
== Next Section == | == Next Section == | ||
+ | |||
+ | Occurrences of Error f0: | ||
+ | |||
+ | {| border="1" | ||
+ | |Tue Mar 9 15:02:11 2010 | ||
+ | |Error on PD 1d(e1/s4) (Error f0) | ||
+ | |- | ||
+ | |Tue Mar 9 15:02:58 2010 | ||
+ | |Error on PD 1c(e1/s5) (Error f0) | ||
+ | |- | ||
+ | |Fri Mar 12 15:00:25 2010 | ||
+ | |Error on PD 30(e2/s1) (Error f0) | ||
+ | |- | ||
+ | |Fri Mar 12 15:01:12 2010 | ||
+ | |Error on PD 2f(e2/s2) (Error f0) | ||
+ | |- | ||
+ | |Wed Mar 17 03:55:03 2010 | ||
+ | |Error on PD 30(e2/s1) (Error f0) | ||
+ | |- | ||
+ | |Wed Mar 17 03:55:50 2010 | ||
+ | |Error on PD 2f(e2/s2) (Error f0) | ||
+ | |- | ||
+ | |Sat Mar 20 11:53:06 2010 | ||
+ | |Error on PD 29(e2/s8) (Error f0) | ||
+ | |- | ||
+ | |Sat Mar 20 11:53:54 2010 | ||
+ | |Error on PD 28(e2/s9) (Error f0) | ||
+ | |- | ||
+ | |Tue Mar 23 19:55:39 2010 | ||
+ | |Error on PD 28(e2/s9) (Error f0) | ||
+ | |- | ||
+ | |Tue Mar 23 19:56:21 2010 | ||
+ | |Error on PD 27(e2/s10) (Error f0) | ||
+ | |- | ||
+ | |Tue Mar 23 23:09:56 2010 | ||
+ | |Error on PD 31(e2/s0) (Error f0) | ||
+ | |- | ||
+ | |Tue Mar 23 23:10:43 2010 | ||
+ | |Error on PD 30(e2/s1) (Error f0) | ||
+ | |- | ||
+ | |Wed Mar 24 22:02:34 2010 | ||
+ | |Error on PD 29(e2/s8) (Error f0) | ||
+ | |- | ||
+ | |Wed Mar 24 22:03:17 2010 | ||
+ | |Error on PD 28(e2/s9) (Error f0) | ||
+ | |- | ||
+ | |Thu Mar 25 22:08:01 2010 | ||
+ | |Error on PD 31(e2/s0) (Error f0) | ||
+ | |- | ||
+ | |Thu Mar 25 22:08:44 2010 | ||
+ | |Error on PD 23(e2/s14) (Error f0) | ||
+ | |- | ||
+ | |Thu Mar 25 22:08:44 2010 | ||
+ | |Error on PD 30(e2/s1) (Error f0) | ||
+ | |- | ||
+ | |} | ||
== Miscellaneous == | == Miscellaneous == |
Revision as of 10:57, 26 March 2010
Contents
CRITICAL DISK STORAGE PROBLEM WITH MD1K-2
There is a serious problem with md1k-2, one of the PowerVault MD1000's connected to s3. It will get into a state where two disks appear to have failed. A two-disk failure when using RAID-5 would mean complete data loss. Fortunately, I've found a remedy that is allowing us to copy the data to a different array.
Dell Higher Education Support 1-800-274-7799 Enter Express Service Code 43288304365 when prompted on the call.
host | service tag | contract end | description | notes |
c8 | CPM1NF1 | 02/15/2011 | PowerEdge 1950 | old schuster storage, moved PERC 5/E to s3 |
s3 | GHNCVH1 | 06/22/2012 | PowerEdge 1950 | connected to md1k-2 via PERC 5/E |
md1k-1 | FVWQLF1 | 02/07/2011 | PowerVault MD1000 | enclosure 3 |
md1k-2 | JVWQLF1 | 02/07/2011 | PowerVault MD1000 | enclosure 2 |
md1k-3 | 4X9NLF1 | 03/06/2011 | PowerVault MD1000 | enclosure 1 |
Problem Description
I've narrowed down the error by looking through the adapter event logs. There will be two errors, one followed about 45 seconds after the first:
Tue Mar 23 23:09:56 2010 Error on PD 31(e2/s0) (Error f0) Tue Mar 23 23:10:43 2010 Error on PD 30(e2/s1) (Error f0)
After that, the virtual disk goes offline.
[root@s3: ~/storage]# MegaCli -LDInfo L1 -a0 Adapter 0 -- Virtual Drive Information: Virtual Disk: 1 (Target Id: 1) Name:md1k-2 RAID Level: Primary-5, Secondary-0, RAID Level Qualifier-3 Size:8.862 TB State: Offline Stripe Size: 64 KB Number Of Drives:14 Span Depth:1 Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Encryption Type: None Number of Dedicated Hot Spares: 1 0 : EnclId - 18 SlotId - 1
If you go into the server room, you'll see flashing amber lights on the disks in md1k-2 slot 0 and 1. I can md1k-2 back using the following procedure (replace slot 0 and 1 which whichever slots are appropriate):
- Take the disks in md1k-2 slots 0 and 1 about half-way out and then push them back in.
- Wait a few seconds for the lights on md1k-2 slots 0 and 1 to return to green.
- Press the power button on s3 until it turns off.
- Press the power button on s3 again to turn it back on.
- Log into s3 as root after it has finished booting.
I then import the foreign configuration. The disk in md1k-2 slot 1 is fine, but the disk in slot 0 needs to be rebuild.
[root@s3: ~/storage]# MegaCli -CfgForeign -Scan -a0 There are 2 foreign configuration(s) on controller 0. Exit Code: 0x00 [root@s3: ~/storage]# MegaCli -CfgForeign -Import -a0 Foreign configuration is imported on controller 0. Exit Code: 0x00 [root@s3: ~/storage]# ./check_disk_states PhysDrv [ 18:0 ] in md1k-2 is in Rebuild state. command to check rebuild progress: MegaCli -PDRbld -ShowProg -PhysDrv [ 18:0 ] -a0 command to estimate remaining rebuild time: ./time_left 18 0 [root@s3: ~/storage]# MegaCli -PDRbld -ShowProg -PhysDrv [ 18:0 ] -a0 Rebuild Progress on Device at Enclosure 18, Slot 0 Completed 56% in 139 Minutes. Exit Code: 0x00 [root@s3: ~/storage]# ./time_left 18 0 time_left: PhysDrv [ 18:0 ] will be done rebuilding in about 1:49:12
After the disk is finished rebuilding, reboot s3 and md1k-2 will be available once again.
Next Section
Occurrences of Error f0:
Tue Mar 9 15:02:11 2010 | Error on PD 1d(e1/s4) (Error f0) |
Tue Mar 9 15:02:58 2010 | Error on PD 1c(e1/s5) (Error f0) |
Fri Mar 12 15:00:25 2010 | Error on PD 30(e2/s1) (Error f0) |
Fri Mar 12 15:01:12 2010 | Error on PD 2f(e2/s2) (Error f0) |
Wed Mar 17 03:55:03 2010 | Error on PD 30(e2/s1) (Error f0) |
Wed Mar 17 03:55:50 2010 | Error on PD 2f(e2/s2) (Error f0) |
Sat Mar 20 11:53:06 2010 | Error on PD 29(e2/s8) (Error f0) |
Sat Mar 20 11:53:54 2010 | Error on PD 28(e2/s9) (Error f0) |
Tue Mar 23 19:55:39 2010 | Error on PD 28(e2/s9) (Error f0) |
Tue Mar 23 19:56:21 2010 | Error on PD 27(e2/s10) (Error f0) |
Tue Mar 23 23:09:56 2010 | Error on PD 31(e2/s0) (Error f0) |
Tue Mar 23 23:10:43 2010 | Error on PD 30(e2/s1) (Error f0) |
Wed Mar 24 22:02:34 2010 | Error on PD 29(e2/s8) (Error f0) |
Wed Mar 24 22:03:17 2010 | Error on PD 28(e2/s9) (Error f0) |
Thu Mar 25 22:08:01 2010 | Error on PD 31(e2/s0) (Error f0) |
Thu Mar 25 22:08:44 2010 | Error on PD 23(e2/s14) (Error f0) |
Thu Mar 25 22:08:44 2010 | Error on PD 30(e2/s1) (Error f0) |