HLab:Steps
From CCGB
HiSeq 2000
- Make sure sample sheet does not include quotes.
- configureBclToFastq.pl --input-dir <BaseCalls_dir> --output-dir <Unaligned> --sample-sheet <BaseCalls_dir>/SampleSheet.csv --no-eamss --mismatches 1 --fastq-cluster-count 0
- output-dir should be under fastq directory, year, run folder, then fastq.
- cd output-dir
- On mal: (screen or) nohup make -j 4
- concat read1, read2 fastq files
- Put symlinks in production folder pointing to fastq files
- Copy data from illumina-9 to rawseq folder
NextSeq 500
- Copy data from learfan back to rawseq directory.
- Copy sample sheet to top directory of run folder, name must be SampleSheet.csv
- On mal: (screen or) nohup bcl2fastq2 --runfolder-dir ~/hlab/reorg/rawseq/<year>/<run folder> -p 3 -d 2 --barcode-mismatches 1
- needs min 16G RAM per core (3x16=48G out of 60G)
- Make symlinks in fastq folder to rawseq Data/Intensities/BaseCalls
- Put symlinks in production folder pointing to fastq files
Trouble shooting
- Things to make sure before you begin
- Make sure the file has unix line endings. If it was created using Excel on a Mac, it will have MacOSX line endings. Run Cathy’s line-ends program to change the line endings.
- ~cathy/bin/line-ends
- Usage: /afs/bx.psu.edu/home/cathy/bin/line-ends <target> <filename> > output
- where target = win, mac, or unix
- Example: /afs/bx.psu.edu/home/cathy/bin/line-ends unix run26_SampleSheet.csv > run26_SampleSheet_endunix.csv
- ~cathy/bin/line-ends