CRITICAL

There is a serious problem with md1k-2, one of the PowerVault MD1000's connected to s3. It will get into a state where two disks appear to have failed. A two-disk failure when using RAID-5 would mean complete data loss. Fortunately, I've found a remedy that is allowing us to copy the data to a different array.

Dell Higher Education Support
1-800-274-7799
Enter Express Service Code 43288304365 when prompted on the call.
host service tag contract end description notes
c8 CPM1NF1 02/15/2011 PowerEdge 1950 old schuster storage, moved PERC 5/E to s3
s3 GHNCVH1 06/22/2012 PowerEdge 1950 connected to md1k-2 via PERC 5/E
md1k-1 FVWQLF1 02/07/2011 PowerVault MD1000 enclosure 3
md1k-2 JVWQLF1 02/07/2011 PowerVault MD1000 enclosure 2
md1k-3 4X9NLF1 03/06/2011 PowerVault MD1000 enclosure 1


I've narrowed down the error by looking through the adapter event logs. There will be two errors, one followed about 45 seconds after the first/

Tue Mar 23 23:09:56 2010   Error on PD 31(e2/s0) (Error f0)
Tue Mar 23 23:10:43 2010   Error on PD 30(e2/s1) (Error f0)